From da5d42f72ccc4ddf8fd652bd98739ae96c5b4fd0 Mon Sep 17 00:00:00 2001 From: bzi Date: Fri, 1 Mar 2019 15:44:03 +0100 Subject: [PATCH] Implement improved sensor publication thresholds --- envisens/envisens_esp_fw/envisens_esp_fw.ino | 10 +++++----- 1 file changed, 5 insertions(+), 5 deletions(-) diff --git a/envisens/envisens_esp_fw/envisens_esp_fw.ino b/envisens/envisens_esp_fw/envisens_esp_fw.ino index 2c42b97..75311ae 100644 --- a/envisens/envisens_esp_fw/envisens_esp_fw.ino +++ b/envisens/envisens_esp_fw/envisens_esp_fw.ino @@ -20,11 +20,11 @@ #define TOPIC_ABHU TOPIC_BASE "abs_humidity" #define TOPIC_AIRQ TOPIC_BASE "air_gas" -#define DIFF_TEMP 0.3 // sensor has only 0.5°C accuracy, triggering on less is ludicrous -#define DIFF_HMID 1.5 // humidity doesn't change that much anyways -#define DIFF_HEAT 0.3 // this one's actually quite active -#define DIFF_ABHU 0.2 // small changes mean quite something -#define DIFF_AIRQ 3 // this one changes in integers +#define DIFF_TEMP 0.5 // sensor has only 0.5°C accuracy, triggering on less is ludicrous +#define DIFF_HMID 2.5 // humidity doesn't change that much anyways +#define DIFF_HEAT 0.5 // this one's actually quite active +#define DIFF_ABHU 0.5 // small changes mean quite something +#define DIFF_AIRQ 5 // this one changes in integers float hmid = 0; // humidity float hmid_r = 0; // humidity