mor1kx-bemicrocv/ip/altera/ddr3/altera_avalon_st_pipeline_base.v

140 lines
4.5 KiB
Coq
Raw Normal View History

2016-08-04 19:22:38 +02:00
// (C) 2001-2015 Altera Corporation. All rights reserved.
// Your use of Altera Corporation's design tools, logic functions and other
// software and tools, and its AMPP partner logic functions, and any output
// files any of the foregoing (including device programming or simulation
// files), and any associated documentation or information are expressly subject
// to the terms and conditions of the Altera Program License Subscription
// Agreement, Altera MegaCore Function License Agreement, or other applicable
// license agreement, including, without limitation, that your use is for the
// sole purpose of programming logic devices manufactured by Altera and sold by
// Altera or its authorized distributors. Please refer to the applicable
// agreement for further details.
// $File: //acds/rel/15.1/ip/avalon_st/altera_avalon_st_pipeline_stage/altera_avalon_st_pipeline_base.v $
// $Revision: #1 $
// $Date: 2015/08/09 $
// $Author: swbranch $
//------------------------------------------------------------------------------
`timescale 1ns / 1ns
module altera_avalon_st_pipeline_base (
clk,
reset,
in_ready,
in_valid,
in_data,
out_ready,
out_valid,
out_data
);
parameter SYMBOLS_PER_BEAT = 1;
parameter BITS_PER_SYMBOL = 8;
parameter PIPELINE_READY = 1;
localparam DATA_WIDTH = SYMBOLS_PER_BEAT * BITS_PER_SYMBOL;
input clk;
input reset;
output in_ready;
input in_valid;
input [DATA_WIDTH-1:0] in_data;
input out_ready;
output out_valid;
output [DATA_WIDTH-1:0] out_data;
reg full0;
reg full1;
reg [DATA_WIDTH-1:0] data0;
reg [DATA_WIDTH-1:0] data1;
assign out_valid = full1;
assign out_data = data1;
generate if (PIPELINE_READY == 1)
begin : REGISTERED_READY_PLINE
assign in_ready = !full0;
always @(posedge clk, posedge reset) begin
if (reset) begin
data0 <= {DATA_WIDTH{1'b0}};
data1 <= {DATA_WIDTH{1'b0}};
end else begin
// ----------------------------
// always load the second slot if we can
// ----------------------------
if (~full0)
data0 <= in_data;
// ----------------------------
// first slot is loaded either from the second,
// or with new data
// ----------------------------
if (~full1 || (out_ready && out_valid)) begin
if (full0)
data1 <= data0;
else
data1 <= in_data;
end
end
end
always @(posedge clk or posedge reset) begin
if (reset) begin
full0 <= 1'b0;
full1 <= 1'b0;
end else begin
// no data in pipeline
if (~full0 & ~full1) begin
if (in_valid) begin
full1 <= 1'b1;
end
end // ~f1 & ~f0
// one datum in pipeline
if (full1 & ~full0) begin
if (in_valid & ~out_ready) begin
full0 <= 1'b1;
end
// back to empty
if (~in_valid & out_ready) begin
full1 <= 1'b0;
end
end // f1 & ~f0
// two data in pipeline
if (full1 & full0) begin
// go back to one datum state
if (out_ready) begin
full0 <= 1'b0;
end
end // end go back to one datum stage
end
end
end
else
begin : UNREGISTERED_READY_PLINE
// in_ready will be a pass through of the out_ready signal as it is not registered
assign in_ready = (~full1) | out_ready;
always @(posedge clk or posedge reset) begin
if (reset) begin
data1 <= 'b0;
full1 <= 1'b0;
end
else begin
if (in_ready) begin
data1 <= in_data;
full1 <= in_valid;
end
end
end
end
endgenerate
endmodule